Exemplar Darknet19 feature generation technique for automated kidney stone detection with coronal CT images.

Publisher:
Elsevier
Publication Type:
Journal Article
Citation:
Artif Intell Med, 2022, 127, pp. 102274
Issue Date:
2022-05
Filename Description Size
1-s2.0-S0933365722000392-main.pdfPublished version2.16 MB
Adobe PDF
Full metadata record
Kidney stone is a commonly seen ailment and is usually detected by urologists using computed tomography (CT) images. It is difficult and time-consuming to detect small stones in CT images. Hence, an automated system can help clinicians to detect kidney stones accurately. In this work, a novel transfer learning-based image classification method (ExDark19) has been proposed to detect kidney stones using CT images. The iterative neighborhood component analysis (INCA) is employed to select the most informative feature vectors and these selected features vectors are fed to the k nearest neighbor (kNN) classifier to detect kidney stones with a ten-fold cross-validation (CV) strategy. The proposed ExDark19 model yielded an accuracy of 99.22% with 10-fold CV and 99.71% using the hold-out validation method. Our results demonstrate that the proposed ExDark19 detect kidney stones over 99% accuracies for two validation techniques. This developed automated system can assist the urologists to validate their manual screening of kidney stones and hence reduce the possible human error.
Please use this identifier to cite or link to this item: