Thermal analysis of duplex three-phase induction motor under fault operating conditions
- Publication Type:
- Journal Article
- Citation:
- IEEE Transactions on Industry Applications, 2013, 49 (4), pp. 1523 - 1530
- Issue Date:
- 2013-08-05
Closed Access
Filename | Description | Size | |||
---|---|---|---|---|---|
2013001081OK.pdf | 1.8 MB |
Copyright Clearance Process
- Recently Added
- In Progress
- Closed Access
This item is closed access and not available.
This paper describes a thermal model for a duplex three-phase induction machine for fault-tolerant applications. The three- and six-phase variations of the duplex three-phase machine operation under fault conditions are considered. Different winding configurations are investigated. Thermal analysis is performed using analytical and finite-element models. An experimental validation is presented for load operating conditions. © 1972-2012 IEEE.